Rear Wiper Switch MUX Input Open
Tests 1 - 3:
Tests 4 - 5:
SYMPTOM
REAR WIPER SWITCH MUX INPUT OPEN
WHEN MONITORED
Ignition ON
SET CONDITION
A Sensor voltage is over 4.76 volts for more than .125 seconds.
POSSIBLE CAUSES
- Intermittent wiring and connectors
- Rear wiper switch MUX circuit open
- Rear wiper switch MUX return circuit open
- Rear wiper switch open
- Body control module