Operation CHARM: Car repair manuals for everyone.

DRB III Safety Information

DRBIII SAFETY INFORMATION

WARNING: EXCEEDING THE LIMITS OF THE ORB MULTIMETER IS DANGEROUS. IT CAN EXPOSE YOU TO SERIOUS OR POSSIBLY FATAL INJURY. CAREFULLY READ AND UNDERSTAND THE CAUTIONS AND THE SPECIFICATION LIMITS.

^ Follow the vehicle manufacturer's service specifications at all times.
^ Do not use the DRBIII if it has been damaged.
^ Do not use the test leads if the insulation is damaged or if metal is exposed.
^ To avoid electrical shock, do not touch the test leads, tips or the circuit being tested.
^ Choose the proper range and function for the measurement. Do not try voltage or current measurements that may exceed the rated capacity.

Do not exceed the limits shown in the table below:





* Ohms cannot be measured if voltage is present. Ohms can be measured only in a non-powered circuit.
^ Voltage between any terminal and ground must not exceed 500v DC or 500v peak AC.
^ Use caution when measuring voltage above 25v DC or 25v AC.
^ Use the low current shunt to measure circuits up to 10A. Use the high current clamp to measure circuits exceeding 10A.
^ When testing for the presence of voltage or current, make sure the meter is functioning correctly. Take a reading of a known voltage or current before accepting a zero reading.
^ When measuring current, connect the meter in series with the load.
^ Disconnect the live test lead before disconnecting the common test lead.
^ When using the meter function, keep the DRB away from spark plug or coil wires to avoid measuring error from outside interference.