Operation CHARM: Car repair manuals for everyone.

High Speed Blower Motor Relay Replacement

REMOVAL
Front
1. Disconnect and isolate the battery negative cable.

Fig. 16 Front:




2. The high speed blower motor relay is retained by a snap fit to the blade of the mounting bracket on the inboard side of the heater-A/C housing. Unsnap the relay from the mounting bracket by sliding it downwards.
3. Unplug the wire harness connector from the high speed blower motor relay

INSTALLATION
Front

Fig. 17 Front:




1. Install the high speed blower motor relay by aligning the relay terminals with the cavities in the relay wire harness connector and pushing the relay firmly into place.
2. Slide the molded receptacle on the high speed blower motor relay case back onto the blade of the mounting bracket until it snaps into place.
3. Connect the battery negative cable.
4. Test the relay operation.