Operation CHARM: Car repair manuals for everyone.

Ambient Temperature Sensor Circuit Open

Test 1 - 2:




Test 3 - 5:






SYMPTOM
AMBIENT TEMPERATURE SENSOR CIRCUIT OPEN

WHEN MONITORED
Whenever the Power Liftgate Module is awake.

SET CONDITION
If the module senses a resistance above 382 k Ohms on the Liftgate Temperature Sensor Signal circuit, this code will set. The normal range for the sensor is 1.2 k to 382 k Ohms. At room temperature (68° F) the resistance will be between 11.2 k and 13.5 k Ohms.

POSSIBLE CAUSES
- DTC present
- Power liftgate module - temperature sense open
- Liftgate temperature sensor signal wire open
- Ground wire open
- Liftgate temperature sensor