P0134
Test 1:
Test 2 - 5:
Test 6 - 7:
SYMPTOM
P0134 - 1/1 O2 SENSOR STAYS AT CENTER
WHEN MONITORED
Engine running for greater than 121 second. Coolant Temperature greater than 66 °C (150.8 °F). Engine in closed loop fuel control mode.
SET CONDITION
O2 signal voltage is between .35 volt and .58 volt for a total of 30 seconds and then O2 signal volt is 1.5 volts for 60 seconds. One trip fault.
POSSIBLE CAUSES
- Good trip equal to zero
- O2 sensor operation
- O2 sensor ground circuit open
- O2 sensor signal open
- O2 sensor ground circuit voltage drop
- O2 sensor signal circuit voltage drop
- PCM