P0952
Test 1-2:
Test 3-6:
SYMPTOM
P0952-AUTOSTICK INPUT CIRCUIT LOW
WHEN MONITORED
The AutoStick circuit is checked every .007 seconds, with the ignition on, and in both AutoStick and non-AutoStick modes.
SET CONDITION
If either the monitored upshift or downshift switch voltages are reported closed in a non AutoStick mode or the monitored voltage drops below 0.3 volts.
POSSIBLE CAUSES
- AUTOSTICK/OD OFF MUX INPUT CIRCUIT SHORT TO GROUND
- AUTOSTICK SWITCH
- TRANSMISSION CONTROL MODULE
- INTERMITTENT WIRING AND CONNECTORS