P0110

Test 1 - 5:




Test 6 - 8:






SYMPTOM
P0110-INTAKE AIR TEMPERATURE SENSOR STUCK

WHEN MONITORED
Engine Running.

SET CONDITION
After 4 warm-up cycles, the PCM did not see a -15 °C (4 °F) change in the IAT Sensor voltage within 200 miles. Two Trip Fault

POSSIBLE CAUSES
- Good Trip Equal To Zero
- (K21) IAT Signal Circuit Shorted To Battery Voltage
- IAT Sensor Voltage Below 0.1 Volts
- (K21) IAT Signal Circuit Open
- (K167) Sensor Ground Circuit Open
- (K21) IAT Signal Shorted To Ground
- (K21) IAT Signal Circuit Shorted To (K167) Sensor Ground
- PCM HIGH