Pedal Sensor Open/Shorted to Ground
Test 1-3:
Test 4-7:
Test 8:
Symptom:
PEDAL SENSOR OPEN/SHORTED TO GROUND
When Monitored:
Continuously.
Set Condition:
When the Adjustable Pedals Module detects a ground condition on the Adjustable Pedal Sensor Signal circuit.
POSSIBLE CAUSES
- INTERMITTENT DTC
- ADJUSTABLE PEDALS SENSOR FEED CIRCUIT OPEN
- ADJUSTABLE PEDALS SENSOR RETURN CIRCUIT OPEN
- ADJUSTABLE PEDALS SENSOR SIGNAL CIRCUIT OPEN
- ADJUSTABLE PEDALS SENSOR FAULT
- APM - INTERNAL FAULT