No Response From Right Sliding Door Control Module
Test 1 - 2:
Test 3 - 5:
Test 6 - 8:
SYMPTOM
NO RESPONSE FROM RIGHT SLIDING DOOR CONTROL MODULE
POSSIBLE CAUSES
- Fused B(+) circuit open
- Ground circuit open
- PCI bus circuit open
- Right sliding door wake up signal wire open
- Right sliding door wake up signal wire short to voltage
- Right sliding door wake up signal wire short to ground
- Body control module - right sliding door wake up ground open
- Right power sliding door module - open