Rear Blower Motor
REMOVALWARNING: REFER TO THE APPLICABLE WARNINGS AND CAUTIONS FOR THIS SYSTEM BEFORE PERFORMING THE FOLLOWING OPERATION.
1. Remove the rear HVAC housing from the vehicle.
2. Disconnect the rear blower motor pigtail wire connector.
NOTE: With the Manual Temperature Control system, the blower motor pigtail wire is connected to a take out and connector of the rear HVAC wire harness. With the Automatic Temperature Control system , the blower pigtail wire is connected to a receptacle on the blower motor power module.
Rear Blower Motor:
3. Remove the three screws that secure the rear blower motor to the outboard side of the rear HVAC housing.
4. Remove the rear blower motor from the rear HVAC housing.
INSTALLATION
1. Position the rear blower motor into the rear HVAC housing.
2. Install the three screws that secure the blower motor to the rear HVAC housing. Tighten the screws to 2 Nm (17 in. lbs.).
3. Reconnect the rear blower motor pigtail wire connector.
NOTE: With the Manual Temperature Control system , the blower pigtail wire is connected to a take out and connector of the rear HVAC wire harness. With the Automatic Temperature Control system, the blower pigtail wire is connected to a receptacle on the blower motor power module.
4. Install the rear HVAC housing.