Driver Front Riser Sensor Out of Range High
Test 1 - 2:
Test 3 - 7:
Test 8 - 9:
SYMPTOM
DRIVER FRONT RISER SENSOR OUT OF RANGE HIGH
WHEN MONITORED
Continuously when the PCI bus is active.
SET CONDITION
This condition is immediately set when the seat motor potentiometer feeds a value higher than the Memory Seat/Mirror/Adjustable Pedals Module has stored in EEPROM. Code will remain for 50 ignition cycles.
POSSIBLE CAUSES
- Memory seat/mirror/adjustable pedals module sensor ground open
- Seat 5 volt supply wire shorted to front riser position signal circuit
- Seat position sensor ground wire open
- 5 volt supply shorted high
- Check voltage on front riser position signal circuit
- Front riser sensor high
- Front riser sensor short to motor
- Memory seat/mirror/adjustable pedals module front riser high
- Stored diagnostic trouble code