Driver Recliner Sensor Out of Range High
Test 1 - 2:
Test 3 - 7:
Test 8 - 9:
SYMPTOM
DRIVER RECLINER SENSOR OUT OF RANGE HIGH
WHEN MONITORED
Continuously when the PCI bus is active.
SET CONDITION
This condition is immediately set when the seat motor potentiometer feeds a value higher than the Memory Seat/Mirror/Adjustable Pedals Module has stored in EEPROM. Code will remain for 50 ignition cycles.
POSSIBLE CAUSES
- Memory seat/mirror/adjustable pedals module sensor ground open
- Seat sensor ground wire open
- 5 volt supply shorted high
- Check voltage on recliner position signal circuit
- Recliner sensor high
- Check recliner sensor short to motor
- Seat 5 volt supply wire shorted to recliner position signal circuit
- Memory seat/mirror/adjustable pedals module recliner sensor high
- Stored diagnostic trouble code