C1205
C1205 - REAR TRACTION CONTROL INLET VALVE CONTROL CIRCUIT LOW
For a complete wiring diagram, refer to the Wiring Information.
- When Monitored:
Continuous.
- Set Condition:
The electrical feedback of the power stage does not correspond with the activation of the respective valve.
DIAGNOSTIC TEST
1. HIGH RESISTANCE IN B+ CIRCUITS
1. Turn key off.
2. Disconnect the ABM harness connector.
Note: Check connector-clean/repair as necessary.
3. Turn key on, engine off.
4. With a test light connected to ground, check (A107) Fused B+, (A111) Fused B+ and (F500) Fused ignition switch output.
Is the test light bright like when connected to the battery?
Yes
- Go To 2.
No
- Repair the high resistance in the circuits.
- Perform ABS Verification Test-VER 1. Refer to ABS Verification Test
2. HIGH RESISTANCE IN GROUND CIRCUITS
1. With a test light connected to B+ check (Z923) Ground and (Z107) Ground.
Is the test light bright like when connected to the battery?
Yes
- Replace the ABM per service information.
- Perform ABS Verification Test-VER 1. Refer to ABS Verification Test
No
- Repair the high resistance in the circuits.
- Perform ABS Verification Test-VER 1. Refer to ABS Verification Test