Manifold Pressure/Vacuum Sensor: Service and Repair
REMOVAL1. Sensor location.
2. Unlock the electrical connector.
3. Remove electrical connector.
4. Turn sensor 1/4 turn counterclockwise.
5. Pull sensor straight up.
6. Remove sensor.
7. Inspect O-ring.
INSTALLATION
1. Clean MAP sensor mounting hole at intake manifold.
2. Check MAP sensor O-ring seal for cuts or tears.
3. Position sensor into intake manifold.
4. Rotate sensor 1/4 turn clockwise for installation.
5. Connect electrical connector to sensor.
6. Lock electrical connector.
7. Connect negative battery cable.