No Response From Cluster
NO RESPONSE FROM CLUSTERNo Response From Cluster:
POSSIBLE CAUSES
- (Z921) (Z108) (Z18) Ground circuit open
- (A944) (M288) (A941) (A114) Fused B+ circuit open
- (F21) (F1) (F983) Fused ignition switch output circuit open
- (D25) PCI BUS circuit open
- Cluster
Diagnostic Test
1. ESTABLISH COMMUNICATIONS WITH OTHER PCI BUS MODULES
Turn the ignition on.
NOTE: Ensure there is PCI bus communication with other modules. If not, refer to the PCI Bus Communication Failure symptom and repair as necessary.
With the DRB, attempt to communicate with the ORC.
With the DRB, attempt to communicate with the ABS.
Q: Was the DRB able to I/D or communicate with either module?
YES: Go To 2
NO: Perform BODY VERIFICATION TEST - VER 1. Body Verification Test
2. (Z921) (Z108) (Z18) GROUND CIRCUIT OPEN
Turn the ignition off.
Disconnect the Cluster harness connectors.
Using a 12-volt test light connected to 12-volts, probe each (Z921) (Z108) (Z18) ground circuit.
Q: Is the test light illuminated for each circuit?
YES: Go To 3
NO: Repair the (Z921) (Z108) (Z18) Ground circuit for an open. Perform BODY VERIFICATION TEST - VER 1. Body Verification Test
3. (A944) (M288) (A941) (A114) FUSED B+ CIRCUIT OPEN
Using a 12-volt test light connected to ground, probe each (A944) (M288) (A941) (A114) Fused B+ circuit.
Q: Is the test light illuminated for each circuit?
YES: Go To 4
NO: Repair the (A944) (M288) (A941) (A114) Fused B+ circuit for an open. Perform BODY VERIFICATION TEST - VER 1. Body Verification Test
4. (F21) (F1) (F983) FUSED IGNITION SWITCH OUTPUT CIRCUIT OPEN
Turn the ignition on.
Using a 12-volt test light connected to ground, probe each (F21) (F1) (F983) Fused Ignition Switch Output circuit.
Q: Is the test light illuminated?
YES: Go To 5
NO: Repair the (F21) (F1) (F983) Fused Ignition Switch Output circuit for an open. Perform BODY VERIFICATION TEST - VER 1. Body Verification Test
5. (D25) PCI BUS CIRCUIT OPEN
Use Scope input cable CH7058, Cable to Probe adapter CH7062, and the red and black test probes.
Connect the scope input cable to the channel one connector on the DRB.
Attach the red and black leads and the cable to probe adapter to the scope input cable.
With the DRBIII(R) select Pep Module Tools.
Select lab scope.
Select Live Data.
Select 12 volt square wave.
Press F2 for Scope.
Press F2 and use the down arrow to set voltage range to 20 volts.
Press F2 again when complete.
Connect the Black lead to the chassis ground.
Connect the Red lead to the PCI Bus circuit in the Cluster connector.
Observe the voltage display on the DRB Lab Scope.
Q: Does the voltage pulse from 0 to approximately 7.5 volts?
YES: Replace the Cluster. Perform BODY VERIFICATION TEST - VER 1. Body Verification Test
NO: Repair the (D25) PCI Bus circuit for an open. Perform BODY VERIFICATION TEST - VER 1. Body Verification Test