P061A
P061A-ETC LEVEL 2 TORQUE PERFORMANCEWHEN MONITORED
Throttle motor is powered.
SET CONDITION
When secondary software determines that the customer requested output is not being achieved by the engine for a period of time. ETC lamp will flash
POSSIBLE CAUSES
- PCM needs to be programmed
- PCM
Always perform the Pre-Diagnostic Troubleshooting procedure before proceeding.
Diagnostic Test
1. PROGRAM THE POWERTRAIN CONTROL MODULE
NOTE: Check the engine for air/vacuum leaks and diagnose any Fuel System Lean/Rich as well as MAP Sensor DTCs before continuing.
Verify the PCM is at the latest calibration (flash level).
NOTE: An intermittent loss of power to the PCM without performing an ETC Relearn procedure may cause this DTC to set.
Flash the Powertrain Control Module if any updates are available.
Start the engine.
Allow the engine to reach normal operating temperature.
Operate the accelerator pedal. (do not exceed 3500 rpm)
With a scan tool, read DTCs.
NOTE: Diagnose any other DTCs that may have set with the P061A.
Q: Does this DTC reset by itself?
YES: Replace and reprogram the Powertrain Control Module. Perform the POWERTRAIN VERIFICATION TEST. Powertrain Verification Test
NO: Test Complete.