Ambient Temperature Sensor Circuit Open
Test 1-2:
Test 3-5:
SYMPTOM
AMBIENT TEMPERATURE SENSOR CIRCUIT OPEN
WHEN MONITORED
Whenever the Power Liftgate Module is awake.
SET CONDITION
If the module senses a resistance above 382K ohms on the Liftgate Temperature Sensor Signal circuit, this code will set. The normal range for the sensor is 1.2K to 382K ohms. At room temperature (68 degrees F) the resistance will be between 11.2 K and 13.5K ohms.
POSSIBLE CAUSES
- DTC present
- Power liftgate module - temperature sense open
- Liftgate temperature sensor signal wire open
- Ground wire open
- Liftgate temperature sensor