Operation CHARM: Car repair manuals for everyone.

P0765

P0765-UD SOLENOID CIRCUIT

When Monitored and Set Condition:

P0765-UD SOLENOID CIRCUIT

When Monitored: Initially at power-up, then every 10 seconds thereafter. Also, immediately after a gear ratio or pressure switch error is detected.

Set Condition: Three consecutive solenoid continuity test failures, or one failure if test is run in response to a gear ratio or pressure switch error.

POSSIBLE CAUSES
- RELATED TCM POWER INPUT DTCS PRESENT
- TRANSMISSION CONTROL RELAY OUTPUT CIRCUIT OPEN
- UD SOLENOID CONTROL CIRCUIT OPEN
- UD SOLENOID CONTROL CIRCUIT SHORT TO GROUND
- UD SOLENOID CONTROL CIRCUIT SHORT TO VOLTAGE
- UD SOLENOID
- POWERTRAIN CONTROL MODULE
- INTERMITTENT WIRING AND CONNECTORS

Step 1:




Step 2-Step 6:




Step 7-Step 9:




Step 10-Step 11: