P1404

Test 1-2:




Test 3-5:






SYMPTOM
P1404-EGR POSITION SENSOR RATIONALITY CLOSED

WHEN MONITORED
Engine running.

SET CONDITION
The EGR flow or valve movement is not what is expected. Two Trip Fault

POSSIBLE CAUSES
- Good trip equal to zero
- EGR solenoid assembly
- EGR position sensor signal circuit shorted to ground
- EGR solenoid control circuit short to ground
- EGR position internal failure
- PCM