Installation - 2.4L
INSTALLATION - 2.4L
The EGR valve and Electrical EGR Transducer are serviced as an assembly (Figure 1).
1. Assemble EGR valve with new gasket onto the cylinder head adaptor.
2. Loose assemble the bolts from EGR valve to EGR tube.
3. Loose assemble the bolts from EGR valve to cylinder head.
4. Tighten bolts from EGR valve to cylinder head to 22.8 Nm (200 ± 25 in. lbs.) torque.
5. Tighten bolts from EGR valve to EGR tube to 11.9 Nm (105 ± 20 in. lbs.) torque.
6. Reconnect vacuum hose and electrical connector to electrical EGR transducer.
Figure 1 EGR VALVE AND TUBE 2.4L