Park Lamp Output 1 Short to Battery
Test 1-3:
SYMPTOM
PARK LAMP OUTPUT 1 SHORT TO BATTERY
WHEN MONITORED
Ignition on.
SET CONDITION
When a battery fault condition is present.
POSSIBLE CAUSES
- Intermittent condition
- Park lamp relay
- Front control module
- Integrated power module