Rear Mode Calibration Fault - MTC
Test 1-3:
Test 4-5:
Test 6-7:
Test 8-10:
Test 11-12:
Test 13-15:
SYMPTOM
REAR MODE CALIBRATION FAULT - MTC
TEST NOTE
This symptom is diagnosed using the test BLEND CALIBRATION FAULT - MTC.
WHEN MONITORED
When the HVAC Door Recalibration is executed.
SET CONDITION
If the rear mode door's span is found outside the tolerance due to: open door actuator electrical circuits; a bad door actuator; broken door linkage; a bound up door; door actuator electrical circuits shorted to voltage; door actuator electrical circuits shorted to ground. A short to voltage or ground on the door actuator electrical circuits will also set door actuator overcurrent faults.
POSSIBLE CAUSES
- Check for actuator circuit test fault messages
- Check for active HVAC DTCs
- Mode linkage/door binding
- Passenger blend linkage/door binding
- Driver blend linkage/door binding
- Recirculation linkage/door binding
- Rear mode linkage/door binding
- Rear blend linkage/door binding
- A/C - heater control module
- Door actuator driver circuit open
- Common door driver circuit open
- Door actuator
- A/C - heater control module
- Rear door actuator driver circuit open
- Rear common door driver circuit open
- Door actuator
- Broken actuator/linkage/door