Right B-Pillar Switch Input Short - BCM
Test 1-3:
SYMPTOM
RIGHT B-PILLAR SWITCH INPUT SHORT - BCM
WHEN MONITORED
Continuously when the BCM is awake.
SET CONDITION
When the BCM senses a switch input less than 0.24 volts for over 10 seconds.
POSSIBLE CAUSES
- DTC present
- Right B-pillar switch shorted
- Right sliding door pillar switch MUX wire short to ground
- Body control module - right sliding door pillar switch circuit shorted