P1797
P1797-MANUAL SHIFT OVERHEATWhen Monitored and Set Condition:
P1797-MANUAL SHIFT OVERHEAT
When Monitored: Whenever the engine is running and transmission is in the AutoStick mode.
Set Condition: If the Engine Temperature exceeds 123°C or 255°F, or the Transmission Temperature exceeds 135°C or 275°F while in AutoStick mode. Note: Aggressive driving or driving in low for extended periods of time in AutoStick mode will set this DTC.
POSSIBLE CAUSES
- MANUAL SHIFT OVERHEAT