Installation
INSTALLATION
WARNING: Use welding gloves when handling heated components. Failure to follow these instructions will result in personal injury.
CAUTION: A bearing heater (2) is used to install Trac-Rite differential case bearings (1). Use only a bearing heater/hot plate and follow manufacture's instructions. Heat components to 100 - 177 Celsius (212� - 350� Max Fahrenheit). Never use an open flame to heat components. Never leave components on heater for and extended amount of time. If component is discolored after heating the component has been overheated and must not be used. Failure to follow these instructions will result in component damage.
1. Heat Trac-Rite(R) differential case bearings (1) with bearing heater (2).
2. With welding gloves or tongs install bearings on differential case.
3. Install open differential case (2) bearings (3) with Installer 8965 (4) and Handle C-4171 (1).
4. Install differential case into housing.