Upper Control Arm Bushings - IFS (HD)
UPPER CONTROL ARM BUSHINGS - IFS (HD)
1. Remove the upper control arm.
2. Secure the control arm in a soft jaw vise.
NOTE: Extreme pressure lubrication must be used on the threaded portions of the tool. This will increase the longevity of the tool and insure proper operation during the removal and installation process.
3. Remove the bushing (3) from the upper control arm (5) using special tool C-4212F (PRESS) (1), 9777-3 (receiver) (4), and 9777-2 (driver) (2).