Installation
INSTALLATION
The Crankcase Pressure (CP) Sensor (5) is mounted on the valve cover (4).
1. Check condition of sensor O-ring.
2. Install sensor (5) into valve cover (4).
3. Install mounting screw (6). Tighten to 3 Nm (27 in. lbs.) torque.
4. Connect electrical connector (7).