Air Inlet Housing Installation
HOUSING-AIR INLET
NOTE: Typical housing shown. RHD model similar.
1. Position the air inlet housing (3) to the top of the HVAC housing (4) and engage the front of the inlet housing to the two plastic retaining tabs (2) located on the top of the HVAC housing.
2. Firmly push down on the rear of the air inlet housing and engage the inlet housing to the HVAC housing. Make sure the two housings are fully engaged to each other.
3. Install the screw (1) that helps secure the rear of the air inlet housing to the HVAC housing. Tighten the screw to 1.2 Nm (10 in. lbs.).
4. Install the HVAC housing assembly HVAC Housing - Installation.