Air Inlet Housing
AIR INLET HOUSING
NOTE: The air inlet housing must be removed from HVAC housing and disassembled for service of the recirculation-air door.
NOTE: If the seals on the air door is deformed or damaged, the air door must be replaced.
1. Position the recirculation-air door (1) into the air inlet housing (2).
CAUTION: Make sure that the recirculation-air door pivot shaft is properly seated in the pivot seat located in the air inlet housing.
2. Align the actuator coupler (3) with the recirculation-air door pivot shaft and install the coupler until the coupler retaining tabs are fully engaged to the air inlet housing. Be sure to install the coupler with the coupler arm located between the two stop tabs on the air inlet housing.
3. Install the two foam insulators (2) into the air inlet housing (1).
4. Install the air inlet housing onto the HVAC housing HVAC Housing - Installation .