Operation CHARM: Car repair manuals for everyone.

Air Inlet Housing







AIR INLET HOUSING

NOTE: The air inlet housing must be removed from HVAC housing and disassembled for service of the recirculation-air door.





1. Remove the air inlet housing (1) from the HVAC housing and place it on a workbench HVAC Housing - Removal and Installation
2. Remove the two foam insulators (2) from the air inlet housing.




3. To remove the recirculation-air door (1) from the air inlet housing (2), first carefully release the retaining tabs of actuator coupler (3) located on the inside surface of the air inlet housing and pull the actuator coupler out of the pivot shaft of the recirculation-air door.

NOTE: If the seals on the air door is deformed or damaged, the air door must be replaced.

4. Remove the recirculation-air door from the air inlet housing.