Water Pump Inlet Tube - Installation
WATER INLET TUBE
1. Position the bypass hose clamps to the center of the hose.
2. Install the bypass hose to the engine.
3. Secure both hose clamps.
4. Install the generator-A/C mounting bracket assembly to the engine. Tighten bolts (number 1 and 2 ) to 54 Nm (40 ft. lbs.). Tighten bolts (number 3 ) to 40 Nm (30 ft. lbs.).
5. Install a new O-ring to the heater hose return tube. Coat the new O-ring with antifreeze before installation.
6. Install the coolant return tube and its mounting bolt to engine.
7. Connect the throttle body control cables.
8. Install the oil dipstick mounting bolt.
9. Install the idler pulley. Tighten the bolt to 54 Nm (40 ft. lbs.).
10. Install the drive belt Serpentine Accessory Drive Belt - Installation.
11. Install the air cleaner assembly Air Cleaner Body - Installation.
12. Install the upper radiator hose to radiator.
13. Connect the wiring harness to the A/C compressor.
14. Connect the battery negative cable.
15. Fill the cooling system Service and Repair.
16. Start and warm the engine. Check for leaks.