HVAC, MTC
U0155-00-LOST COMMUNICATION WITH CLUSTER/CCN
For a complete wiring diagram, refer to the Wiring Information. Electrical Diagrams
- When Monitored:
With the ignition on.
Battery voltage between 10 and 16 Volts.
Ignition Off Draw (IOD) fuse installed.
Totally Integrated Power Module (TIPM) is configured correctly.
- Set Condition:
Bus messages not received from the Cluster/CCN for approximately two to five seconds.
VERIFY DIAGNOSTIC TROUBLE CODE (DTC) IS ACTIVE
NOTE: Make sure the IOD fuse is installed and 12-volt battery voltage is between 10 and 16 Volts before proceeding.
1. Using the scan tool, read active HVAC DTCs.
Is this DTC active?
Yes
- Perform the diagnostic procedure for U0155-Lost Communication With Cluster/CCN. Totally Integrated Power Module (TIPM)
No
- Perform the Stored Lost Communication DTC diagnostic procedure. Stored Lost Communication DTCs