Installation






INSTALLATION






NOTE: After installing Evaporative System Integrity Monitor (ESIM) switch, the electrical connector on the switch must be in the 3 O'clock position. This step must be done for proper ESIM switch operation.

1. Install ESIM switch (3) to vapor canister (1) and rotate 1/4 turn clockwise until the lock tab (2) engages. Make sure electrical connector is in the 3 O'clock position.
2. Install vapor canister filter line (4) to ESIM switch (3).
3. Connect electrical connector (5) to ESIM switch (3).