EXHAUST TEMPERATURE SENSOR










1. Position DPF downstream temperature sensor (3) into DPF. Tighten to 25 Nm (18 ft. lbs.).
2. Connect downstream temperature sensor electrical connector (4).
3. Position DPF upstream temperature sensor (2) into DPF. Tighten to 25 Nm (18 ft. lbs.).
4. Connect upstream temperature sensor electrical connector (1).
5. Install engine cover.