B1BC7
B1BC7-DEPLOYMENT DATA RECORD FULL
Theory of Operation
When powered, the Occupant Restraint Controller (ORC) performs an internal self test. The repair of this fault condition does not involve any external circuitry and centers on verifying the integrity of the module's internal memory. The Event Data Recorder (EDR) can not be erased of deployment records, records are locked.
- When Monitored:
With the ignition on within four seconds of powering up. The module's on board diagnostics continuously performs internal circuit tests.
- Set Condition:
This DTC will set if the module identifies an out of range internal circuit. This DTC once set will be latched for the life of this ORC. The DTC will always stay Active.
Always perform the Pre-Diagnostic Troubleshooting procedure before proceeding. Restraints System Pre-Diagnostic Procedure.
1. CHECK FOR ACTIVE DTC
1. Turn the ignition on.
2. With the scan tool, read ORC DTCs.
Is the Deployment Data Record Full DTC active?
Yes
- Go To 2
No
- Perform the RESTRAINTS SYSTEM VERIFICATION TEST. Restraints System Verification Test.
2. REPLACE THE OCCUPANT RESTRAINT CONTROLLER
WARNING: Turn the ignition off disconnect the 12-volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
WARNING: If the Occupant Restraint Controller (ORC) is dropped at any time, it must be replaced. Failure to take the proper precautions can result in accidental airbag deployment. Failure to follow these instructions may result in possible serious or fatal injury.
Repair
- Replace the Occupant Restraint Controller. Occupant Restraint Controller - Removal.
- Perform the RESTRAINTS SYSTEM VERIFICATION TEST. Restraints System Verification Test.