P0601
P0601-INTERNAL MEMORY CHECKSUM INVALID
For a complete wiring diagram, refer to the Wiring Information.
- When Monitored:
With the ignition on.
- Set Condition:
Internal checksum for software failed, does not match calculated value. One trip fault, three good trips to clear.
Always perform the Pre-Diagnostic Troubleshooting procedure before proceeding. Pre-Diagnostic Troubleshooting Procedure.
POWERTRAIN CONTROL MODULE (PCM)
NOTE: Diagnose any CMP or CKP Sensor faults before continuing. Check for intermittent loose CMP or CKP connections.
The Powertrain Control Module is reporting internal errors, view repair to continue.
Repair
- Replace and program the Powertrain Control Module. Powertrain Control Module - Removal.
- Perform the POWERTRAIN VERIFICATION TEST. Powertrain Verification Test.