B11DA
B11DA-96-ITOS CABIN TEMPERATURE SENSOR - COMPONENT INTERNAL FAILURE
For a complete wiring diagram, refer to the Wiring Information.
Theory of Operation
The HVAC A/C Heater Control uses a variety of sensors to adjust HVAC operation to obtain optimal performance. These sensors are continuously monitored by the A/C Heater Control to assure that they are in a calibrated range and are functioning properly. The Integrated Thermal Optical Sensor (ITOS) in mounted in the front of the A/C Heater Control and is a non-serviceable component.
- When Monitored:
With the ignition on.
- Set Condition:
The A/C Heater Control detects a malfunction in the Integrated Thermal Optical Sensor (ITOS).
Always perform the HVAC Pre-Diagnostic Troubleshooting procedure before proceeding. HVAC Pre-Diagnostic Troubleshooting Procedure.
REPLACE THE A/C HEATER CONTROL
This DTC detects a problem with the ITOS which is an internal sensor circuit in the controller and is not serviceable.
Repair
- Inspect the A/C Heater Control for debris that my be inhibiting the functionality of the Integrated Thermal Optical Sensor and clean as necessary. If no problem is found, replace and program the A/C Heater Control. A/C And Heater Control - Removal.
- Perform the HVAC VERIFICATION TEST. HVAC Verification Test.