43 - Right Front Isolation Solenoid Shorted
Symptom List:LEFT FRONT DUMP SOLENOID OPEN - 46
LEFT FRONT DUMP SOLENOID SHORTED - 48
LEFT FRONT ISOLATION SOLENOID OPEN - 45
LEFT FRONT ISOLATION SOLENOID SHORTED - 47
REAR DUMP SOLENOID OPEN - 52
REAR DUMP SOLENOID SHORTED - 54
REAR ISOLATION SOLENOID OPEN - 51
REAR ISOLATION SOLENOID SHORTED - 53
RIGHT FRONT DUMP SOLENOID OPEN - 42
RIGHT FRONT DUMP SOLENOID SHORTED - 44
RIGHT FRONT ISOLATION SOLENOID OPEN - 41
RIGHT FRONT ISOLATION SOLENOID SHORTED - 43
Test 1-3:
Test 4:
Test Note: All symptoms listed above are diagnosed using the same tests. The title for the tests will be LEFT FRONT DUMP SOLENOID OPEN - 46.
LEFT FRONT DUMP SOLENOID OPEN - 46
When Monitored:
Ignition on.
Set Condition:
When there is low logic feedback voltage from the solenoid when it is expected to be high (solenoid not energized).
LEFT FRONT DUMP SOLENOID SHORTED - 48
When Monitored:
Ignition on.
Set Condition:
When there is high logic feedback voltage from the solenoid when it is supposed to be low (solenoid energized).
LEFT FRONT ISOLATION SOLENOID OPEN - 45
When Monitored:
Ignition on.
Set Condition:
When there is low logic feedback voltage from the solenoid when it is expected to be high (solenoid not energized).
LEFT FRONT ISOLATION SOLENOID SHORTED - 47
When Monitored:
Ignition on.
Set Condition:
When there is high logic feedback voltage from the solenoid when it is supposed to be low (solenoid energized).
REAR DUMP SOLENOID OPEN - 52
When Monitored:
Ignition on.
Set Condition:
When there is low logic feedback voltage from the solenoid when it is expected to be high (solenoid not energized).
REAR DUMP SOLENOID SHORTED - 54
When Monitored:
Ignition on.
Set Condition:
When there is high logic feedback voltage from the solenoid when it is supposed to be low (solenoid energized).
REAR ISOLATION SOLENOID OPEN - 51
When Monitored:
Ignition on.
Set Condition:
When there is low logic feedback voltage from the solenoid when it is expected to be high (solenoid not energized).
REAR ISOLATION SOLENOID SHORTED - 53
When Monitored:
Ignition on.
Set Condition:
When there is high logic feedback voltage from the solenoid when it is supposed to be low (solenoid energized).
RIGHT FRONT DUMP SOLENOID OPEN - 42
When Monitored:
Ignition on.
Set Condition:
When there is low logic feedback voltage from the solenoid when it is expected to be high (solenoid not energized).
RIGHT FRONT DUMP SOLENOID SHORTED - 44
When Monitored:
Ignition on.
Set Condition:
When there is high logic feedback voltage from the solenoid when it is supposed to be low (solenoid energized).
RIGHT FRONT ISOLATION SOLENOID OPEN - 41
When Monitored:
Ignition on.
Set Condition:
When there is low logic feedback voltage from the solenoid when it is expected to be high (solenoid not energized).
RIGHT FRONT ISOLATION SOLENOID SHORTED - 43
When Monitored:
Ignition on.
Set Condition:
When there is high logic feedback voltage from the solenoid when it is supposed to be low (solenoid energized).
POSSIBLE CAUSES
- INTERMITTENT DTC
- OPEN FUSED B(+) AND FUSED IGNITION SWITCH OUTPUT (RUN)
- OPEN GROUND CIRCUITS
- CAB - INTERNAL CONCERN