Operation CHARM: Car repair manuals for everyone.

B10AD





B10AD-RIGHT BLEND DOOR TRAVEL TOO SMALL



Theory of Operation

After the initial installation of the A/C Heater Control, the controller is calibrated to each individual blend/mode door actuator. These calibrations are stored as in the number of pulses it takes to move the door from one stop to another. The A/C Heater Control drives the Door Actuators by the use of Door Driver circuit and a Common Door Driver circuit and monitors all door actuator pulses to detect door movement in both directions. Most of the door actuators share a common door driver circuit but each door actuator has its own unique driver circuit. Due to shared circuitry, similar DTCs can set at the same time for multiple actuators depending upon the type of circuit malfunction, its location, and the direction the actuator is moving when the malfunction is present.

- When Monitored:
When ever an Actuator Calibration Test is performed.

- Set Condition:
The A/C Heater Control uses a pulse feedback to the controller to detect the total door movement range. If the amount of pulses required to move the door completely in both directions is less than what the controller has stored in its memory, this DTC will set. If an Actuator Calibration Test is performed and the A/C Heater Control detects a valid range of the door movement span in both directions, the DTC will change from Active to Stored and will stay in the controllers memory for 100 ignition cycles.





Always perform the HVAC Pre-Diagnostic Troubleshooting procedure before proceeding. Initial Inspection and Diagnostic Overview.

1. CHECK FOR RELATED DTCS
1. Ignition on, engine not running.
2. With the scan tool, read HVAC DTCs.

Are there any Door Control - Circuit Open or Door Control - Performance or Incorrect Operation DTCs present?

Yes

- Testing and Inspection Perform the appropriate diagnostic procedure.

No

- Go To 2

2. CHECK IF DTC IS ACTIVE
1. Ignition on, engine not running.
2. With the scan tool, read HVAC DTCs.

Is this DTC active?

Yes

- Go To 4

No

- Go To 3

3. PERFORM HVAC ACTUATOR CALIBRATION TEST
1. With the scan tool, perform the HVAC Actuator Calibration Test.

Did this DTC change from Stored to Active while performing the HVAC Actuator Calibration Test?

Yes

- Go To 4

No

- Go To 6

4. CHECK THE PASSENGER BLEND DOOR
1. Remove the Passenger Blend Door Actuator and check the Passenger Blend Door for binding and full travel.

Is there any problem with the Blend Door movement?

Yes

- Repair or replace the Passenger Blend Door as necessary.
- Perform the HVAC VERIFICATION TEST. HVAC Verification Test.

No

- Go To 5

5. CHECK THE PASSENGER BLEND DOOR ACTUATOR
1. Replace the Passenger Blend Door Actuator.
2. With the scan tool, erase HVAC DTCs and perform the HVAC Actuator Calibration Test.

Did this DTC reset?

Yes

- Replace and program the A/C Heater Control.
- Perform the HVAC VERIFICATION TEST. HVAC Verification Test.

No

- Test complete.
- Perform the HVAC VERIFICATION TEST. HVAC Verification Test.

6. CHECK THE WIRING AND CONNECTORS
1. The conditions necessary to set the DTC are not present at this time.
2. Using the schematics as a guide, inspect the wiring and connectors specific to this circuit.
3. Check for an intermittent condition by inspecting the related wiring harness for chafed, pierced, pinched, partially broken wires.
4. Check the connectors for broken, bent, pushed out, spread, corroded, or contaminated terminals.
5. Wiggle the wiring and connectors while checking for shorted and open circuits.
6. With the scan tool, check the Environmental Data to help identify the conditions in which the DTC was set.

Were there any problems found?

Yes

- Repair as necessary.
- Perform the HVAC VERIFICATION TEST. HVAC Verification Test.

No

- Test complete.