Looseness
Lateral movement can be observed at the
fan blade tip under various temperature conditions because of the type bearing used. This movement should not exceed 1/4 inch (6.5 mm) as measured at the fan tip. If this lateral movement does not exceed specifications, there is no cause for replacement.