B10 - Jumpered Load Test
^ Disconnect alternator plug.
^ Connect jumper wires between B+ blades and wiring plug.
^ Repeat load test measuring voltage to jumper wires from battery negative clamp.
^ Voltage should rise 0.5 volt or more.
Voltage rise 0.5 volt or more -- Service alternator to starter relay wiring. Go to B2. B2 - Base Voltage and No Load Test
Voltage rise less than 0.5 volt -- Go to B11. B11 - Load Repeat (F Terminal)