Operation CHARM: Car repair manuals for everyone.

Vacuum Check Valve: Testing and Inspection

Vacuum Check Valve:






Apply 54 kPa (16 in Hg) vacuum to "check" side of the valve and trap. If vacuum remains above 50 kPa (15 in Hg) for 10 seconds, the valve is acceptable.