End Play Check
Special Tools:
1. Insert End Play Checking Toot into the torque converter pump drive.
1 Position End Play Checking Tool.
2 Tighten the inner post until the tool is securely locked.
2. Attach Dial Indicator With Bracketry to End Play Checking Tool.
- Position the dial indicator bottom on the converter pump drive hub and zero the dial.
3. Lift up on End Play Checking Tool and note the dial indicator reading.
- If the reading exceeds end play limits, replace the torque converter.
4. Remove the dial indicator and tool.