Principles of Operation (How Does It Work ?)
Evaporative Emission System (Non-OBD II):
Evaporative Emission System (OBD II):
Evaporative Emissions Canister Purge Valve
The EVAP canister purge valve is controlled by the Powertrain Control Module (PCM). The EVAP canister purge valve controls the flow of fuel vapors from the EVAP canister to the engine intake manifold during various engine operating modes. The EVAP canister purge valve is normally closed.
Evaporative Emission Canister
Fuel vapors from the fuel tank are stored in the EVAP canister. When the engine is running, the vapors are purged from the EVAP canister for combustion. Sometimes vehicles use multiple canisters. This would be dependent upon the size and number of the fuel tanks used on a specific vehicle.
Canister Vent Solenoid (OBD II vehicles only)
During the Evaporative Emission Running Loss System Test Monitor, Evaporative Emissions Repair Verification Drive Cycle and the Evaporative Emission System Leak Test the canister vent solenoid is closed, to allow either a vacuum to be drawn on the fuel tank or to hold a specified pressure in the system. The canister vent solenoid is normally open.
Fuel Tank Pressure (FTP) Sensor (OBD II vehicles only)
The fuel tank pressure sensor is used to measure the fuel tank pressure during the evaporative emissions monitor test. It is also used to control excessive fuel tank pressures by forcing the EVAP system to purge. The fuel tank pressure sensor can be either tank mounted or remotely mounted in the fuel vapor control valve hose (tube) as it crosses over the fuel tank.
Fuel Vapor Vent Valve (FVV) Assembly
The Fuel Vapor Vent Valve (FVV) assembly is mounted on the top of the fuel tank. It is used to control the flow of fuel vapors entering the EVAP system. The head portion of the assembly prevents the fuel tank from overfilling during refueling. The assembly also has a spring float, which prevents liquid fuel from entering the vapor delivery system under severe handling or vehicle rollover conditions. In the upright position, the open bottom of the float will lift and shut off the orifice. Under severe handling conditions, the spring will push the float closed when angles allow liquid fuel to reach the orifice. In a rollover condition, the weight of the open bottom float and spring pressure will close the orifice.
Fuel Filler Pipe Check Valve
The fuel filler pipe check valve is an integral part of the fuel tank or the fuel filler pipe. It is intended to prevent liquid fuel from re-entering the fuel filler pipe from the fuel tank on refueling or rollover conditions.
Fuel Filler Cap
The fuel filler cap is used to prevent fuel spill and to close the EVAP system to the atmosphere.
Evaporative Emissions System Monitor (OBD II vehicles only)
When a fault occurs, the EVAP system monitor is reset to NO and a Diagnostic Trouble Code (DTC) is set in the PCM memory. After the DTC is repaired, the vehicle drive cycle must be completed to reset the monitor in preparation for inspection and maintenance testing.
EVAP Running Loss System Test
To start the testing, conditions of stable purging and vehicle speed must be satisfied. During the first stage, the EVAP canister vent solenoid is closed while the EVAP canister purge valve remains open, applying and building vacuum in the system as indicated by the Fuel Tank Pressure (FTP) sensor. This phase checks for major leaks in the EVAP system.
In the second stage, the EVAP canister purge valve closes and the system looks for minimal decay rate in the EVAP vacuum, indicating the absence of any small EVAP system leaks.
The last stage is entered only if stage two of the leak test has failed and checks whether the failed test was due to excess vapor generation. It monitors fuel vapor generation rate. Initially the canister vent solenoid is opened to equalize EVAP system pressure to atmosphere. Then the canister vent solenoid is closed, allowing pressure to build if vapor generation is present in sufficient quantity. If the rate of generation is found to be too high, the EVAP running loss system leak test is aborted. If not, then a small leak is diagnosed.