Initial Inspection - Instrument Panel Illumination
INSPECTION AND VERIFICATIONNOTE: Upon installation of a new instrument cluster, the module must be reconfigured.
1. Verify the customer concern by operating the instrument illumination.
2. Visually inspect for obvious signs of electrical damage; refer to the chart.
VISUAL INSPECTION CHART
Electrical
- Central junction box (CJB) fuse(s):
- 6 (15A)
- 22 (10A)
- Wiring harness
- Headlamp switch
- Dimmer module (Navigator only)
3. If the fault is not visually evident, determine the symptom and proceed to the Symptom Chart. Diagnosis By Symptom - Instrument Panel Illumination