Auxiliary Temperature Blend Door Actuator
AUXILIARY TEMPERATURE BLEND DOOR ACTUATORRemoval and Installation
1. Remove the air conditioning and heater assembly.
2. Disconnect the vacuum line.
3. Remove the vacuum control motor.
1 Remove the screw.
2 Detach and remove the vacuum control motor
4. Disconnect the vacuum control motor from the airflow mode door.
5. To install, reverse the removal procedure.