Solenoid Body
Solenoid BodyMaterial:
Upper, Lower, Accumulator and Solenoid Body, Disassembled View (Part 1):
Upper, Lower, Accumulator and Solenoid Body, Disassembled View (Part 2):
Upper, Lower, Accumulator and Solenoid Body, Disassembled View (Part 3):
Disassembly
1. Remove the manual valve.
2. Remove and discard the solenoid body electrical connector O-ring seal.
3. Remove the main control valve body electrical harness.
- Remove the 2 bolts.
- Disconnect the electrical connectors.
- Lift the tab and twist and push the bulkhead connector through the solenoid body.
- Remove the solenoid body electrical harness.
4. NOTE: Mark the location of each solenoid for correct installation.
Remove the E-clips and remove the solenoids.
5. Remove the transmission fluid temperature (TFT) sensor by lifting the tab and rotating counterclockwise.
6. Note the location and length of each bolt. Remove the 4 bolts and remove the top half of the main control valve body.
7. NOTE: The gasket should not be cleaned or reused.
Remove and discard the gasket.
8. Remove the bolts, backing plate and discard the gasket. Clean and inspect the components.
Assembly
1. Install a new gasket and the backing plate.
- Tighten to 13 Nm (10 lb-ft).
2. Install a new filter screen gasket.
3. NOTE: Tighten the bolts in a crisscross pattern to prevent the gasket from becoming distorted.
Assemble the top and bottom halves of the solenoid body.
- Tighten to 13 Nm (10 lb-ft).
4. Install the TFT sensor.
5. Install the shift solenoids with the E-clips.
6. Install a new O-ring seal on the solenoid body electrical connector in the uppermost groove. Lubricate the O-ring seal with clean automatic transmission fluid.
7. Install the solenoid body harness and connect the connectors.
8. Install the manual valve.