Test C: DTC C1095 - ABS Hydraulic Pump Motor Circuit Failure
PINPOINT TEST C: DTC C1095 - ABS HYDRAULIC PUMP MOTOR CIRCUIT FAILURERefer to Vehicle/Diagrams, Vehicle Dynamic Systems for schematic and connector information.
Normal Operation
The operating voltage required to operate the hydraulic pump is in a range between 10 and 16 volts.
Fused battery voltage is supplied by battery junction box (BJB) fuse 9 (60A) along circuit SBB09 (RD). Ground is provided along circuit GD120 (BK/GN).
Possible Causes
^ Fuse
^ Circuit open
^ Hydraulic pump motor
^ Anti-lock brake system (ABS) module