Operation CHARM: Car repair manuals for everyone.

Generator On-Vehicle Tests

GENERATOR ON-VEHICLE TESTS

CAUTION:
- To prevent damage to the generator, do not make the jumper wire connections except as directed.
- Do not allow any metal object to come in contact with the housing and the internal diode cooling fins with the key in the ON or OFF positions. A short circuit may result and burn out the diodes.


NOTE:
- Battery posts and cable clamps must be clean and tight for accurate meter indications.
- Refer to the battery tester manual for complete directions for testing the charging system.

1. Turn off all of the lamps and the electrical components.
2. Place the transmission in NEUTRAL and apply the parking brake.
3. Carry out the Load Test and No Load Test according to the following component tests:

Generator On-Vehicle Tests - Load Test
1. Switch the tester to the ammeter function.
2. Connect the positive and negative leads of the tester to the corresponding battery terminals.
3. Connect the current probe to the generator B+ circuit 38 (BK/OG).







4. With the engine running at approximately 2,000 rpm, adjust the tester load bank to determine the output of the generator. The generator output should be greater than the graph shown. If not, Refer back to the pinpoint test or GO to Symptom Chart. Symptom Related Diagnostic Procedures

Generator On-Vehicle Tests No Load Test
1. Switch the tester to the voltmeter function.
2. Connect the voltmeter positive lead to the generator B+ circuit 38 (BK/OG) and the negative lead to ground.
3. Turn all of the electrical accessories off.
4. With the engine running at approximately 2,000 rpm, check the generator output voltage. The voltage should be between 13.2 and 15.5 volts. If not, Refer to the pinpoint test or GO to Symptom Chart. Pinpoint Tests Symptom Related Diagnostic Procedures