Operation CHARM: Car repair manuals for everyone.

On Board Diagnostic (OBD) Drive Cycle

ON BOARD DIAGNOSTIC (OBD) DRIVE CYCLE

Description of On Board Diagnostic (OBD) Drive Cycle
The following procedure is designed to execute and complete the OBD monitors and to clear the Ford P1000, I/M readiness code. To complete a specific monitor for repair verification, follow steps 1 through 4, then continue with the step described by the appropriate monitor found under the OBD Monitor Exercised column. For the EVAP/secondary AIR monitor to run, the ambient air temperature must be between 4.4 to 37.8°C (40 to 100°F), and the altitude below 2,438 meters (8,000 feet). If the PI000 code must be cleared in these conditions, the powertrain control module (PCM) must detect them once (twice on some applications) before the EVAP monitor can be bypassed and diagnostic trouble code (DTC) P1000 is cleared. The EVAP bypassing procedure is described in the following drive cycle.

The OBD drive cycle is carried out using a scan tool. Refer to the manufacturer's instruction manual for each described function.

A detailed description for clearing the DTCs is found. Refer to Clear The Continuous Diagnostic Trouble Codes (DTCs) And Reset The Emission Monitors Information in The Powertrain Control Module (PCM). Clear the Continuous Diagnostic Trouble Codes (DTCs) and Reset the Emission Monitors Information In the Powertrain Control Modu

Drive Cycle Recommendations

WARNING: Strict observance of posted speed limits and attention to driving conditions are mandatory when proceeding through the following drive cycles. Failure to follow these instructions may result in personal injury.

1. Most OBD monitors complete more readily using a steady foot driving style during cruise or acceleration modes. Operating the throttle in a smooth fashion minimizes the time required for monitor completion.
2. The fuel tank level should be between 1/2 and 3/4 full with 3/4 full being the most desirable.
3. The evaporative monitor can operate only during the first 30 minutes of engine operation. When executing the procedure for this monitor, stay in part throttle mode and drive in a smooth fashion to minimize fuel slosh.
4. When bypassing the EVAP engine soak times, the PCM must remain powered (key ON) after clearing the continuous DTCs and relearning emission diagnostic information.


On Board Diagnostic (OBD) Drive Cycle (Part 1):






On Board Diagnostic (OBD) Drive Cycle (Part 2):






For best results, follow each of the steps as accurately as possible.